智慧用电(dian)(dian)(dian)厂家让用电(dian)(dian)(dian)更(geng)安全、更(geng)智能,智慧用电(dian)(dian)(dian)通过物(wu)联网技术(shu)对引发(fa)电(dian)(dian)(dian)气(qi)火灾的(de)主(zhu)要因素 ( 导线(xian)温度、电(dian)(dian)(dian)流和漏电(dian)(dian)(dian)流等(deng) )进行不间断的(de)数据跟踪与统(tong)计分析(xi),实时发(fa)现(xian)电(dian)(dian)(dian)气(qi)线(xian)路和用电(dian)(dian)(dian)设备存在(zai)的(de)安全隐患(如线(xian)缆温度异常、过载及漏电(dian)(dian)(dian)流越限等(deng)),经云平台大数据分析(xi),即时向安全管理人(ren)员(yuan)发(fa)送预(yu)警信息,指导其(qi)开展(zhan)隐患治理,达(da)到(dao)消除潜在(zai)的(de)电(dian)(dian)(dian)气(qi)火灾危险(xian),
智慧用电联网监测平台_智慧用电厂家让用电更安全、更智能
智慧(hui)用电(dian)(dian)(dian)(dian)(dian)通(tong)(tong)过(guo)物联网技术对引发电(dian)(dian)(dian)(dian)(dian)气火(huo)灾(zai)的(de)(de)主要(yao)因素 ( 导(dao)线(xian)温度(du)、电(dian)(dian)(dian)(dian)(dian)流(liu)和漏(lou)(lou)电(dian)(dian)(dian)(dian)(dian)流(liu)等(deng) )进行(xing)不间(jian)断的(de)(de)数(shu)(shu)据跟踪与(yu)统(tong)计(ji)分(fen)析,实(shi)时发现(xian)电(dian)(dian)(dian)(dian)(dian)气线(xian)路(lu)(lu)和用电(dian)(dian)(dian)(dian)(dian)设备(bei)存在(zai)的(de)(de)安(an)全隐患(huan)(如线(xian)缆温度(du)异常、过(guo)载及漏(lou)(lou)电(dian)(dian)(dian)(dian)(dian)流(liu)越(yue)限等(deng)),经云(yun)平台大数(shu)(shu)据分(fen)析,即时向安(an)全管(guan)理人员发送预警信(xin)息,指导(dao)其开展隐患(huan)治理,达到(dao)消除潜(qian)在(zai)的(de)(de)电(dian)(dian)(dian)(dian)(dian)气火(huo)灾(zai)危险,实(shi)现(xian)“防患(huan)于未然”的(de)(de)目的(de)(de)。本设备(bei)具备(bei)四路(lu)(lu)温度(du)检测(ce)、三路(lu)(lu)电(dian)(dian)(dian)(dian)(dian)流(liu)检测(ce)和一路(lu)(lu)漏(lou)(lou)电(dian)(dian)(dian)(dian)(dian)流(liu)检功能,有(you)三种(zhong)通(tong)(tong)读模式(shi)选择:485总线(xian)通(tong)(tong)讯(xun),GPRS网络通(tong)(tong)讯(xun)和LORA无(wu)线(xian)通(tong)(tong)讯(xun)。
一、智慧用电安全探测器详细技术参数
额定(ding)工作(zuo)电(dian)压:AC220V/12V 50Hz
剩余电(dian)流报警设(she)定值:20mA~1000mA
调节精度:1mA
主回(hui)路额定工(gong)作电流:0~225A
通讯模(mo)式:RS485/GPRS网络通讯
声光报警:支持
执行标准(zhun)号:GB14287.2-2014
电流报(bao)警设定值:1A-1000A
温度(du)报(bao)警设定值:0°C~140°C
报警延(yan)时时间:0.3s~50s
通(tong)讯频(pin)率:900-1800Mhz
环境温度:-10°C~+60°C
相(xiang)对湿(shi)度(du):≤90%、不(bu)凝露(lu)
二、设计依据
一(yi):是GB50045-95(2005版)《高层民(min)用建(jian)筑(zhu)(zhu)设计防火(huo)(huo)规范》,其中在条文(wen)9.5.1里规定:高层建(jian)筑(zhu)(zhu)内(nei)火(huo)(huo)灾危险性大、人员密集等场所宜设置漏电火(huo)(huo)灾报(bao)警系统。
二:是GB50016-2014《建筑设计防火规范》,在条文10.2.7里规定:下(xia)列场所(suo)(suo)宜设置剩余(yu)电流动作电气火灾监控(kong)系统。这些(xie)场所(suo)(suo)包括(kuo)各种(zhong)类型(xing)的影剧院、馆所(suo)(suo)、仓(cang)库、住(zhu)宅小(xiao)区、医院、商店、学校等(deng)等(deng)。
三:国(guo)家标准《建筑电(dian)(dian)气(qi)火灾预(yu)防要求和检测方法》有关(guan)条文(wen)也明(ming)确(que)要求“应(ying)在电(dian)(dian)源(yuan)进线端设置自(zi)动切断(duan)电(dian)(dian)源(yuan)或报警(jing)的剩余(yu)电(dian)(dian)流(liu)动作保护器”。
四:电(dian)(dian)(dian)气(qi)火(huo)灾监控(kong)系统的产品应满足:GB14287.1-2005《电(dian)(dian)(dian)气(qi)火(huo)灾监控(kong)设备(bei)》、 GB14287.2-2005《剩余电(dian)(dian)(dian)流式电(dian)(dian)(dian)气(qi)火(huo)灾监控(kong)探(tan)测(ce)器》、GB14287.3-2005《测(ce)温式电(dian)(dian)(dian)气(qi)火(huo)灾监控(kong)探(tan)测(ce)器》
五:电气(qi)火灾(zai)监控系(xi)统的安装和运行(xing)应满足GB13955-2005《剩余(yu)电流动作保护装置安装和运行(xing)》
六:电气火灾监控系统(tong)的(de)供电应满足GB50052《供配电系统(tong)设计规(gui)范》的(de)要求
七:电(dian)(dian)气(qi)火灾(zai)(zai)监控系(xi)统的(de)设(she)计应满足《电(dian)(dian)气(qi)火灾(zai)(zai)监控系(xi)统的(de)设(she)计方法》的(de)要求(暂电(dian)(dian)气(qi)火灾(zai)(zai)监控系(xi)统行规(gui)定(ding))
三、系统组成
我公司所研发的电(dian)气(qi)火(huo)灾(zai)监(jian)控系(xi)统是有三种模式所组成的,分别是独立联网(wang)型电(dian)气(qi)火(huo)灾(zai)监(jian)控系(xi)统和RS485总线型联网(wang)电(dian)气(qi)火(huo)灾(zai)监(jian)控系(xi)统以及LORA无线联网(wang)型电(dian)气(qi)火(huo)灾(zai)监(jian)控系(xi)统三种系(xi)统。
*种
独立联网型电(dian)气火灾监控(kong)系统(tong)
本套电(dian)气(qi)火灾监控(kong)系(xi)统(tong)由(you)独立(li)联网型剩余电(dian)流(liu)式电(dian)气(qi)火灾监控(kong)探测(ce)主(zhu)机和开口式/闭口式电(dian)流(liu)互感器(qi)、开口式/闭口式漏(lou)电(dian)流(liu)互感器(qi)以及(ji)温度传感器(qi)、物联网流(liu)量卡所组成的一套独立(li)联网型电(dian)气(qi)火灾监控(kong)系(xi)统(tong)。(系(xi)统(tong)拓扑图(tu)如下图(tu)所示)
通过独立(li)联网型剩余电(dian)流(liu)式(shi)电(dian)气火灾监控探(tan)测主机(ji)插入物(wu)联网流(liu)量卡,直接采集电(dian)流(liu)互(hu)感器以及(ji)剩余电(dian)流(liu)互(hu)感器和温度传(chuan)感器的数据,再通过GPRS网络把数据上传(chuan)到平台,从而下发数据到终端用户。
其次,我(wo)们 还可通(tong)过综合监控火灾管理主(zhu)机(ji)来实(shi)现,通(tong)过剩余(yu)电流式电气火灾监控探测(ce)主(zhu)机(ji)拥有总(zong)线RS485和(he)GPRS网络通(tong)讯(xun)两种(zhong)模(mo)(mo)式以及LORA无线模(mo)(mo)式,可实(shi)现三种(zhong)模(mo)(mo)式系统组合。
第二种
RS485联网(wang)电气火(huo)灾监控系(xi)统
通过RS485总线连接方式,可(ke)接20路剩余电(dian)(dian)(dian)流(liu)式电(dian)(dian)(dian)气(qi)火(huo)(huo)灾监控(kong)探(tan)测器。只需(xu)要在综合电(dian)(dian)(dian)气(qi)火(huo)(huo)灾监控(kong)管理主机(ji)上(shang)插(cha)入一张(zhang)物联网(wang)流(liu)量卡,再(zai)由(you)485总线把前端剩余电(dian)(dian)(dian)流(liu)式电(dian)(dian)(dian)气(qi)火(huo)(huo)灾监控(kong)探(tan)测器的数(shu)据采集(ji)过来,通过GPRS网(wang)络把数(shu)据上(shang)传到云平台,从而下发数(shu)据到终(zhong)端用户。
第三种
LORA联网电气火灾监控系统
LORA的(de)无(wu)线(xian)方式,在(zai)一(yi)定的(de)无(wu)线(xian)距离(li)之内,是没有(you)数(shu)(shu)量的(de)限制,只要距离(li)足够,就(jiu)可以连接无(wu)数(shu)(shu)个剩余电流(liu)(liu)式电气(qi)火灾(zai)监控(kong)探(tan)测器,但是前提下(xia),综合电气(qi)火灾(zai)监控(kong)管理主机需(xu)要加入LORA无(wu)线(xian)模(mo)块和插入物联(lian)网(wang)流(liu)(liu)量卡,以及(ji)剩余电流(liu)(liu)式电气(qi)火灾(zai)监控(kong)探(tan)测器也(ye)是需(xu)要加入LORA无(wu)线(xian)模(mo)式,与485的(de)区别就(jiu)是少了布线(xian)的(de)麻烦(fan),同时在(zai)无(wu)线(xian)距离(li)里还没有(you)限制数(shu)(shu)量连接。
图2 智(zhi)慧用电安全(quan)管理系统云平台架构图
四、工作原理
其基本(ben)原(yuan)理是,当电气设(she)备(bei)中(zhong)(zhong)的(de)电流(liu)、温度(du)等参数发(fa)(fa)生异常或(huo)突变(bian)时,终端探(tan)(tan)测(ce)头(tou)(如剩余电流(liu)互感(gan)器(qi)(qi)、温度(du)传感(gan)器(qi)(qi)等)利用电磁场感(gan)应原(yuan)理、温度(du)效应的(de)变(bian)化对该(gai)信(xin)(xin)息进行(xing)采(cai)集,并(bing)输送到(dao)监(jian)控(kong)探(tan)(tan)测(ce)主(zhu)机或(huo)者探(tan)(tan)测(ce)器(qi)(qi)里,经放大、A/D转换、CPU对变(bian)化的(de)幅值进行(xing)分(fen)析(xi)、判断(duan),并(bing)与报(bao)(bao)警设(she)定(ding)值进行(xing)比较(jiao),一(yi)旦超出设(she)定(ding)值则(ze)发(fa)(fa)出报(bao)(bao)警信(xin)(xin)号,同时也输送到(dao)监(jian)控(kong)设(she)备(bei)中(zhong)(zhong),再经监(jian)控(kong)设(she)备(bei)进一(yi)步(bu)识别(bie)、判定(ding),当确认可能会发(fa)(fa)生火(huo)灾(zai)(zai)时,监(jian)控(kong)主(zhu)机发(fa)(fa)出火(huo)灾(zai)(zai)报(bao)(bao)警信(xin)(xin)号,点(dian)亮报(bao)(bao)警指(zhi)示(shi)灯,发(fa)(fa)出报(bao)(bao)警音响,同时在液(ye)晶显示(shi)屏上显示(shi)火(huo)灾(zai)(zai)报(bao)(bao)警等信(xin)(xin)息。值班人(ren)员(yuan)则(ze)根据以上显示(shi)的(de)信(xin)(xin)息,迅速到(dao)事故现(xian)场进行(xing)检查处理,并(bing)将报(bao)(bao)警信(xin)(xin)息发(fa)(fa)送到(dao)集中(zhong)(zhong)控(kong)制台(tai)。
五、功能描述
1、功能
24小时不间断时时监视(shi)用(yong)电(dian)设(she)备泄露电(dian)流的(de)(de)变化(hua)、线缆接头温度的(de)(de)变化(hua),为配电(dian)设(she)备的(de)(de)预防(fang)性(xing)维护提供(gong)依据,有效预防(fang)电(dian)气火(huo)灾的(de)(de)发生,保(bao)障用(yong)户财(cai)产(chan)的(de)(de)安全。
对整个监(jian)控系统范围内(nei)的(de)电(dian)能(neng)(neng)质(zhi)量(liang)和(he)电(dian)能(neng)(neng)可靠性,漏电(dian)电(dian)流(liu)及线缆温(wen)度(du)状况进(jin)行实(shi)时的(de)监(jian)视。实(shi)时监(jian)视系统电(dian)压偏差(cha)、频率(lv)偏差(cha)、不平衡度(du)、功率(lv)因数、谐波含量(liang),电(dian)压闪变,剩(sheng)余电(dian)流(liu)及温(wen)度(du)等(deng)电(dian)能(neng)(neng)质(zhi)量(liang)问题(ti),评估电(dian)能(neng)(neng)质(zhi)量(liang)是否符(fu)合标(biao)准。记录(lu)扰动时的(de)波形,作(zuo)为电(dian)能(neng)(neng)质(zhi)量(liang)分(fen)析和(he)故障分(fen)析的(de)依据(ju)。
支(zhi)持(chi)(chi)四路温度(du),支(zhi)持(chi)(chi)三(san)(san)路电(dian)(dian)(dian)流(liu),支(zhi)持(chi)(chi)一路剩余(yu)电(dian)(dian)(dian)流(liu),可同时接入四路温度(du)和三(san)(san)路电(dian)(dian)(dian)流(liu)以及一路剩余(yu)电(dian)(dian)(dian)流(liu),也可只接两路温度(du)和一路电(dian)(dian)(dian)流(liu)以及一路剩余(yu)电(dian)(dian)(dian)流(liu)。
多种方式(shi)选择,拥有RS485和GPRS通讯方式(shi)以(yi)及LORA无线(xian)模式(shi),根据不同的(de)现场(chang)环境采取合(he)适的(de)方式(shi)去安装施(shi)工。
支持(chi)(chi)独立式联(lian)网(wang)(wang)使(shi)用(yong)(yong)也支持(chi)(chi)组合式联(lian)网(wang)(wang)使(shi)用(yong)(yong)。
2、操作使用
按照以下操作教程步骤即可学会操作
1、插入(ru)电话语音(yin)卡,接入(ru)GPRS天线,接入(ru)220V或者(zhe)12V电源
2、通过(guo)接线端口示意(yi)图对应接线
上图为上排接线端口示意图,分别可(ke)接220V以(yi)及(ji)温(wen)度(du)传(chuan)感器(qi),*路(lu)温(wen)度(du)传(chuan)感器(qi)一条(tiao)接T1以(yi)及(ji)COM口即可(ke),第(di)二路(lu)温(wen)度(du)传(chuan)感器(qi)就(jiu)接T2以(yi)及(ji)COM口就(jiu)可(ke)以(yi),其他两路(lu)如此类推。
上(shang)图为(wei)下(xia)排(pai)接(jie)(jie)(jie)(jie)(jie)(jie)线端口(kou)示意(yi)图,分(fen)别可(ke)接(jie)(jie)(jie)(jie)(jie)(jie)12V供电(dian)(dian),485接(jie)(jie)(jie)(jie)(jie)(jie)口(kou)A与(yu)B两(liang)根(gen)(gen)线,漏电(dian)(dian)互(hu)(hu)感(gan)器(qi)为(wei)两(liang)根(gen)(gen)线,一(yi)根(gen)(gen)接(jie)(jie)(jie)(jie)(jie)(jie)IN接(jie)(jie)(jie)(jie)(jie)(jie)口(kou),另(ling)外一(yi)根(gen)(gen)也(ye)是接(jie)(jie)(jie)(jie)(jie)(jie)IN接(jie)(jie)(jie)(jie)(jie)(jie)口(kou),*个电(dian)(dian)流互(hu)(hu)感(gan)器(qi)一(yi)根(gen)(gen)接(jie)(jie)(jie)(jie)(jie)(jie)IN1接(jie)(jie)(jie)(jie)(jie)(jie)口(kou),另(ling)外一(yi)根(gen)(gen)也(ye)接(jie)(jie)(jie)(jie)(jie)(jie)IN1接(jie)(jie)(jie)(jie)(jie)(jie)口(kou),其他(ta)两(liang)个电(dian)(dian)流互(hu)(hu)感(gan)器(qi)也(ye)一(yi)样。
3、通上(shang)220V或者12V的(de)电后,开始使用手机(ji)编辑短(duan)信(xin),短(duan)信(xin)内(nei)容(rong)为:usr+六(liu)位用户编号,dm:+IP地址,发送(song)到已经插入(ru)机(ji)器上(shang)的(de)电话语音卡(ka)(ka)的(de)卡(ka)(ka)号,收(shou)到回信(xin)后,通讯(xun)灯会闪(shan)烁同时会常(chang)亮(liang),此(ci)时断电,把(ba)原来的(de)电话语音卡(ka)(ka)拔出(chu),然后再更换物联网流(liu)量卡(ka)(ka)再开启即(ji)可(ke)。
4、可(ke)在现(xian)场(chang)通(tong)过面盖的(de)设(she)置(zhi)(zhi)(zhi)键(jian)进(jin)(jin)行(xing)对电流值以及漏电值和温度值进(jin)(jin)行(xing)设(she)置(zhi)(zhi)(zhi),设(she)置(zhi)(zhi)(zhi)方法:按(an)住设(she)置(zhi)(zhi)(zhi)键(jian)3秒进(jin)(jin)入(ru)(ru)设(she)置(zhi)(zhi)(zhi),*设(she)置(zhi)(zhi)(zhi)的(de)是(shi)剩(sheng)(sheng)余(yu)电流值,可(ke)通(tong)过查(cha)(cha)询键(jian)调动小(xiao)(xiao)数点和上下(xia)(xia)翻查(cha)(cha)键(jian)进(jin)(jin)行(xing)设(she)置(zhi)(zhi)(zhi)值的(de)大小(xiao)(xiao),设(she)置(zhi)(zhi)(zhi)完(wan)后再按(an)下(xia)(xia)设(she)置(zhi)(zhi)(zhi)键(jian),进(jin)(jin)入(ru)(ru)电流值大小(xiao)(xiao)设(she)置(zhi)(zhi)(zhi),也(ye)是(shi)跟设(she)置(zhi)(zhi)(zhi)剩(sheng)(sheng)余(yu)电流值一(yi)样的(de)操作方法,最(zui)后再按(an)下(xia)(xia)设(she)置(zhi)(zhi)(zhi)键(jian),进(jin)(jin)入(ru)(ru)温度最(zui)高值设(she)置(zhi)(zhi)(zhi),设(she)置(zhi)(zhi)(zhi)完(wan)之后再按(an)住设(she)置(zhi)(zhi)(zhi)键(jian)即可(ke)保(bao)存(cun)退(tui)出。
5、可通过云(yun)平台远程(cheng)设置电流值和(he)漏电值和(he)温度(du)值。
未来(lai),力(li)(li)安科技将会持续加大在电(dian)气(qi)火(huo)灾隐(yin)患防治方面的投入力(li)(li)度,力(li)(li)争(zheng)让每个配(pei)电(dian)系统(tong)都能拥(yong)有一个用(yong)电(dian)安全(quan)卫士,构建(jian)起更(geng)专业、更(geng)成熟、更(geng)全(quan)面的用(yong)电(dian)安全(quan)服务体系,为实(shi)现(xian)“让电(dian)气(qi)安全(quan)管理变得更(geng)简单!”的奋(fen)斗目标而(er)不懈(xie)努力(li)(li)